National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
High voltage power supply for dielectric strength
Klejma, Michael ; Červinka, Dalibor (referee) ; Martiš, Jan (advisor)
This thesis deals with a choice of proper solution of high votlage source with regulated DC output in range of 0 – 50 kV. Source will be used for testing of electrical insulators, with function of displaying voltage at which breakdown of the insulator occured. Due to low output current up to 1 mA it is possible to use a cascade voltage multiplier as suitable solution. The voltage multiplier is powered by switching-mode power supply with high voltage pulse transformer. The inverter uses single-acting innovative topology that enables a supply of alternating current to the voltage multiplier. This solution is simple, but an analysis of operation is difficult, as will be described in details in this thesis. Realization and testing of the source has been successfully done, but the source had problems with its own EMC. After debugging, requested parameters have been achieved.
Voltage amplifier for Electrical field generation
Nedbal, Jan ; Szabó, Zoltán (referee) ; Kubásek, Radek (advisor)
This bachelor’s thesis is about design and practical realization of the voltage amplifier for generating an electric field defined trace. First part is introduced design of function generator and a DC power supply symmetric. In the second part is the design and simulation of power amplifier in class A and high voltage DC source. The last part is consists of measurements on a function generator, power amplifier and high voltage DC source.
Laboratory test equipment for IGBT transistors
Chvátlina, Pavel ; Vorel, Pavel (referee) ; Patočka, Miroslav (advisor)
This master’s thesis describes the function and realization of the laboratory test equipment designed for measuring and analysing of collector current iC and voltage uCE courses during the opening and closing process of a power IGBT transistor. The opening and closing times toff and ton of the new power transistor IGBT are changing in the range from tenths to the ones s, so the reading of current iC and voltage uCE proceeds in a very short time. The measuring circuit of this test equipment is based on a short-time discharging of a condenser battery to the inductive load over the measured transistor. Consequently it is possible to replace the power supply whose maximum output power would otherwise have to be in the range of ones MW. In the final part of this thesis there are described properties and design of a high-frequency sensor with the Rogowski coil, which can be used for reading collector current course during opening and closing time of the measured transistor IGBT. Collector current iC and voltage uCE courses can be analysed with a storage oscilloscope.
High voltage power supply for dielectric strength
Klejma, Michael ; Červinka, Dalibor (referee) ; Martiš, Jan (advisor)
This thesis deals with a choice of proper solution of high votlage source with regulated DC output in range of 0 – 50 kV. Source will be used for testing of electrical insulators, with function of displaying voltage at which breakdown of the insulator occured. Due to low output current up to 1 mA it is possible to use a cascade voltage multiplier as suitable solution. The voltage multiplier is powered by switching-mode power supply with high voltage pulse transformer. The inverter uses single-acting innovative topology that enables a supply of alternating current to the voltage multiplier. This solution is simple, but an analysis of operation is difficult, as will be described in details in this thesis. Realization and testing of the source has been successfully done, but the source had problems with its own EMC. After debugging, requested parameters have been achieved.
Voltage amplifier for Electrical field generation
Nedbal, Jan ; Szabó, Zoltán (referee) ; Kubásek, Radek (advisor)
This bachelor’s thesis is about design and practical realization of the voltage amplifier for generating an electric field defined trace. First part is introduced design of function generator and a DC power supply symmetric. In the second part is the design and simulation of power amplifier in class A and high voltage DC source. The last part is consists of measurements on a function generator, power amplifier and high voltage DC source.
Laboratory test equipment for IGBT transistors
Chvátlina, Pavel ; Vorel, Pavel (referee) ; Patočka, Miroslav (advisor)
This master’s thesis describes the function and realization of the laboratory test equipment designed for measuring and analysing of collector current iC and voltage uCE courses during the opening and closing process of a power IGBT transistor. The opening and closing times toff and ton of the new power transistor IGBT are changing in the range from tenths to the ones s, so the reading of current iC and voltage uCE proceeds in a very short time. The measuring circuit of this test equipment is based on a short-time discharging of a condenser battery to the inductive load over the measured transistor. Consequently it is possible to replace the power supply whose maximum output power would otherwise have to be in the range of ones MW. In the final part of this thesis there are described properties and design of a high-frequency sensor with the Rogowski coil, which can be used for reading collector current course during opening and closing time of the measured transistor IGBT. Collector current iC and voltage uCE courses can be analysed with a storage oscilloscope.